NeuroTrac Sports XL

VAT Exempt
ual channel Sports XL device has all the features of Sports device, plus: Stronger symmetrical stimulation, with the reduced Pulse Width: 50 – 330 μS. 2 lead wires for each channel giving a total of 8 electrode positions. 21 Pre-set Sports’s programmes and 3 Customisable programmes. Advanced multi-phase programmes where treatment is split into time phases with different stimulation parameters. Model number: ETS201. STIM Dual channel: individually isolated circuits. Amplitude: 0-90 mA into 500 Ohm load; actual mA will tend to be less than indicated due to electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 86 mA, at 1500 Ohms load the maximum will be limited to 65 mA. Type: Constant current, maximum output voltage 180 Volts +10 / -30 Volts Waveform: Symmetrical, rectangular bi-phasic with zero DC current. Selectable pulse width: 50 μS – 330 μS [2% accuracy]. Pulse Rate selection: in the continuous mode 2 – 100 Hz [2% accuracy]. Time duration of the treatment selectable: 1 minute to 90 minutes. Low Battery Indicator: If the battery goes below 6.9 volts +/- 0.2 volts the battery symbol will flash on/off once every second. Open Electrode Detect: If an open circuit is detected at the output of channel A or B the output current will be reset at zero. Ramp up time 0.1 – 9.9 seconds. If the battery voltage is below 6.6 (+/- 0.2) volts the unit will not turn on.
In stock
SKU
8-TM002
£122.38 £101.98
ual channel Sports XL device has all the features of Sports device, plus: Stronger symmetrical stimulation, with the reduced Pulse Width: 50 – 330 μS. 2 lead wires for each channel giving a total of 8 electrode positions. 21 Pre-set Sports’s programmes and 3 Customisable programmes. Advanced multi-phase programmes where treatment is split into time phases with different stimulation parameters. Model number: ETS201. STIM Dual channel: individually isolated circuits. Amplitude: 0-90 mA into 500 Ohm load; actual mA will tend to be less than indicated due to electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 86 mA, at 1500 Ohms load the maximum will be limited to 65 mA. Type: Constant current, maximum output voltage 180 Volts +10 / -30 Volts Waveform: Symmetrical, rectangular bi-phasic with zero DC current. Selectable pulse width: 50 μS – 330 μS [2% accuracy]. Pulse Rate selection: in the continuous mode 2 – 100 Hz [2% accuracy]. Time duration of the treatment selectable: 1 minute to 90 minutes. Low Battery Indicator: If the battery goes below 6.9 volts +/- 0.2 volts the battery symbol will flash on/off once every second. Open Electrode Detect: If an open circuit is detected at the output of channel A or B the output current will be reset at zero. Ramp up time 0.1 – 9.9 seconds. If the battery voltage is below 6.6 (+/- 0.2) volts the unit will not turn on.
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
VAT Exempt Yes